Standard configuration
HFC R404a environmental friendly refrigerant;
Multi-function operating panel and uP controller;
Ultra-thin evaporator;
Hot gas defrosting system;
DC12V/24V operating voltage;
HFC134a or 452a refrigerant options may be available per prior agreement.
Safety devices
- Input or output H and L voltage protection;
- Thermal protection;
- System HP/LP cutout switch;
- Liquid injection and oil return protection devices;
- Wire harness ESD insulation methods which improve system protection from electromagnetic interference;
- Vehicle battery protection device.
Operation and control component
-
Microprocessor control system;
-
Automatic / manual defrost;
-
Digital display
-
Fahrenheit or Celsius display for set point temperature and return air temperature, parameters setting alarm codes.
Product key features
01
Suitable for all electric vans;
02
Save fuel consumption, environmentally-friendly;
03
Integrated design, compressor and electrical parts are all located in condenser;
04
Special battery unit protection, avoids large impulse current;
05
Suitable for high DC voltage:DC200-700V;
06
Constant cooling capacity, not affected by vehicle speed;
07
Evaporator copper tubes with aluminum fins, fast cooling, large airflow;
08
Optional:Heating, electric stand-by function and CAN telecommunications.
Specifications
Model | KXE-185R | |||
Cooling Capacity Ambient +30℃(86℉) | Temperature | Watts | Btu/hr | |
On road | 0℃/+32℉ | 2000 | 6840 | |
-20℃/0℉ | 1100 | 3760 | ||
Electric standby | 0℃/+32℉ | 2000 | 6840 | |
-20℃/0℉ | 1100 | 3760 | ||
Evaporator Airflow Volume | 950m³/h | |||
Condenser | Coil | Micro-channel | ||
Fan motor quantity | 1pcs | |||
Dimension | 890*720*200mm | |||
Weight | 60kg | |||
Evaporator | Coil | Copper tube&aluminum fin | ||
Fan motor quantity | 1pcs | |||
Dimension | 720*575*170mm | |||
Weight | 12kg | |||
Compressor Displacement | 15cc | |||
Refrigerant Charge | R404a/1.1kg | |||
Defrost | Hot gas defrost(automatic&manual) | |||
Unit Operation Voltage | DC12V | |||
Electric Standby&Heating Function | Optional | |||
Application-box length&interal volume | 5m³(-20℃)~10m³(0℃) |
Note:
Application-internal volume is for reference only, it depends on insulation material (K factor should be equal or lower than 0.32Watts/m²℃), ambient temperature, precooling, load and type of goods etc.