Standard configuration
HFC R404a environmental friendly refrigerant;
Multi-function operating panel and uP controller;
Ultra-thin evaporator;
Hot gas defrosting system;
DC12V/24V operating voltage;
HFC134a or 452a refrigerant options may be available per prior agreement.
Specifications
| Model | KXE-365R | |||
| Cooling Capacity Ambient +30℃(86℉) | Temperature | Watts | Btu/hr | |
| 0℃/+32℉ | 3560 | 12140 | ||
| -20℃/-4℉ | 1850 | 6310 | ||
| Evaporator Airflow Volume | 1830m³/h | |||
| Condenser | Coil | Micro-channel | ||
| Fan motor quantity | 2pcs | |||
| Dimension | 1150*850*240mm | |||
| Weight | 78kg | |||
| Evaporator | Coil | Copper tube&aluminum fin | ||
| Fan motor quantity | 2pcs | |||
| Dimension | 1085*660*225mm | |||
| Weight | 21kg | |||
| Rated Power | 2.2kW(0℃/30℃)PMAX<4.0kW | |||
| Compressor | Electric hermetic 35.6cc/rev | |||
| Refrigerant Charge | R404A/1.3KG | |||
| Defrost | Hot gas defrost | |||
| Unit Operation Voltage | DC12V/DC24V | |||
| Vehicle VoltageD | DC200V~700V | |||
| Electric Standby&Heat | Optional | |||
| Application-box interal volume | 12m³(-20℃)~20m³(0℃) | |||
Note: